C. Control Buttons
The control board features RESET, SERVICE 1, and SERVICE 2 Buttons
1. RESET Button
• Press briey to go to initial harvest cycle.
• Press and hold for 3 seconds to enter control board setting mode. For details about
control board settings, see "III.D. Control Board Setting Mode and Control Board
Settings."
2. SERVICE 1 and SERVICE 2 Buttons
• Press the "SERVICE 1" or "SERVICE 2" button briey to display the current freeze
cycle termination temperature (Control Board Setting 2). This setting controls dimple
diameter. For details about adjusting the dimple diameter, see "III.H.1. Dimple
Diameter." NOTICE! Do not decrease dimple size below 3/16" (5 mm).
• Press and hold the "SERVICE 1" button for 3 seconds to enter information display and
model code setting mode. For details about information display and model code setting,
see "III.F. Model Code Setting Mode."