Hoshizaki KM-2000SRF3 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Les fabricants de glaçons Hoshizaki KM-2000SRF3. Hoshizaki KM-2000SRF3 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - KM-2000SRH3

ISSUED:OCT. 9, 1998KM-2000SWF3KM-2000SRF3KM-2000SWH3KM-2000SRH3MODELSERVICE MANUALHOSHIZAKISTACKABLE CRESCENT CUBERNO:73081DEC. 16, 2003REVISED:

Page 2 - IMPORTANT

10[b] KM-2000SRF3, KM-2000SRH3 Evaporator Spray Tube Water Valve Expansion Valve Water Supply InletCheck ValveHot Gas ValveJunction BoxCon

Page 3 - CONTENTS

112. CONTROLLER BOARD[a] SOLID-STATE CONTROL1) A HOSHIZAKI exclusive solid-state control is employed in KM-2000SWF3, KM-2000SRF3, KM-2000SWH3, and

Page 4

122) Defrost TimerThe defrost cycle starts when the Float Switch opens and completes the freeze cycle. Butthe Defrost Timer does not start counting u

Page 5 - I. SPECIFICATIONS

13problem occurs. At startup a 5 second delay occurs while the board conducts an internaltimer check. A short beep occurs when the power switch is

Page 6

14(Control Products HOSHIZAKI001 Board)to the K1 connector. If there is a white wire, place the switch in the C position. If thisswitch is placed in

Page 7 - 3. CONDENSING UNIT

15(Control Products HOS-001A Board)

Page 8 - MODEL: URC-20F

16 4. Defrost Timer stops counting. Defrost cycle is completed and freeze cycle starts.[c] SEQUENCE1st Cycle [KM-2000SWF3, KM-2000SRF3, KM-

Page 9 - 1. CONSTRUCTION

172nd Cycle and after with pump drain[KM-2000SWF3, KM-2000SRF3, KM-2000SWH3 and KM-2000SRH3]IMPORTANTFreeze cycle time is limited to 60 minutes evenif

Page 10

182nd Cycle and after with no pump drain[KM-2000SWF3, KM-2000SRF3, KM-2000SWH3 and KM-2000SRH3]IMPORTANTFreeze cycle time is limited to 60 minutes eve

Page 11 - 2. CONTROLLER BOARD

19DIP SWITCH NO. 1 2 3 4 5 6 7 8 9 10 OFF OFF ON ON ON ON OFF OFF OFF OFF[d] CONT

Page 12

2HOSHIZAKI AMERICA, INC.618 Highway 74 SouthPeachtree City, GA 30269Attn: HOSHIZAKI Technical Support DepartmentPhone: 1-800-233-1940 Technical Ser

Page 13

201) Defrost ControlA thermistor (Semiconductor) is used for a defrost control sensor. The resistance variesdepending on the Suction Line temperature

Page 14

213) Drain TimerThe Drain Timer is factory-adjusted, and no adjustment is required.SETTING TIMEDip Switch Dip SwitchNo. 3 No. 4 T1 T2OFF OFF 10 second

Page 15

226) Bin ControlCAUTIONWhen the ambient temperature is below 45°F, the Bin Control Thermostatoperates to stop the icemaker even if the Ice Storage Bin

Page 16 - [c] SEQUENCE

23(iv) After Step (iii), de-energize the unit and confirm that the Defrost Timer is in theminimum position. Disconnect the resistor from the Controll

Page 17

24III. TECHNICAL INFORMATION1. WATER CIRCUIT AND REFRIGERANT CIRCUIT[a] KM-2000SWF3, KM-2000SWH3

Page 18

25[b] KM-2000SRF3, KM-2000SRH3

Page 19 - KM-2000S_H3

262. WIRING DIAGRAMS[a] KM-2000SWF3 KM-2000SWH3[b] KM-2000SRF3 KM-2000SRH3Pressure SwitchCut-out 384 PSIGCut-in 284 ± 21.3 PSIG+21.30Pre

Page 20

273. TIMING CHART*1 The icemaker does not complete a defrost cycle in the first 2 or 3 minutes. See “II. 2. [d] CONTROLS ANDADJUSTMENTS.”

Page 21

28*1 The Pump Motor waits for 2 seconds before starting a drain cycle. See “II. 2. [d] CONTROLS ANDADJUSTMENTS.”*2 The icemaker does not complete a d

Page 22

294. PERFORMANCE DATA[a] KM-2000SWF3, KM-2000SWH3Note: Pressure data is recorded first 5 minutes in freezing cycle. The data not in bold should be u

Page 23

3Please review this manual. It should be read carefully before the icemaker is serviced ormaintenance operations are performed. Only qualified servic

Page 24 - III. TECHNICAL INFORMATION

30[b] KM-2000SRF3, KM-2000SRH3Note: Pressure data is recorded first 5 minutes in freezing cycle. The data not in bold should be used for ref

Page 25 - [b] KM-2000SRF3, KM-2000SRH3

31 PROBLEM POSSIBLE CAUSE REMEDY[1] The icemaker a) Power Supply 1. “OFF” position. 1. Move to “ON” position. will not start 2. Loose c

Page 26 - 2. WIRING DIAGRAMS

32 PROBLEM POSSIBLE CAUSE REMEDYl) Controller Board 1. Defective. 1. See “II.2[e] CHECKING CONTROLLER BOARD.” m) Interlock Switc

Page 27 - 3. TIMING CHART

33 PROBLEM POSSIBLE CAUSE REMEDY[5] No water a) Water Supply Line 1. Water pressure too low and 1. Check and get comes from water l

Page 28 - ADJUSTMENTS.”

342. EVAPORATOR IS FROZEN UP PROBLEM POSSIBLE CAUSE REMEDY[1] Freeze cycle a) Float Switch 1. Leads short-circuit or 1. Check and replace.

Page 29 - [a] KM-2000SWF3, KM-2000SWH3

35 PROBLEM POSSIBLE CAUSE REMEDY[1] Icemaker will a) Bin Control 1. Set too cold. 1. Adjust warmer. not stop when Thermostat 2. Def

Page 30

36V. REMOVAL AND REPLACEMENT OF COMPONENTSIMPORTANTEnsure all components, fasteners and thumbscrews are securely in place afterthe equipment is servi

Page 31 - 1. NO ICE PRODUCTION

375) Disconnect the Vacuum Pump, and attach a Refrigerant Service Cylinder to the High-side line. Remember to loosen the connection, and purge the ai

Page 32

383. REMOVAL AND REPLACEMENT OF COMPRESSORIMPORTANTAlways install a new Drier every time the sealed refrigeration system isopened. Do not replace the

Page 33

3915) Evacuate the system, and charge it with refrigerant. See the Nameplate for the required refrigerant charge.16) Connect the Terminals, and

Page 34 - 2. EVAPORATOR IS FROZEN UP

42. BRAZING ... 373. REMOVAL AND REPLACEME

Page 35 - 3. LOW ICE PRODUCTION

405. REMOVAL AND REPLACEMENT OF EXPANSION VALVEIMPORTANTSometimes moisture in the refrigerant circuit exceeds the Drier capacity andfreezes up at the

Page 36

416. REMOVAL AND REPLACEMENT OF HOT GAS VALVE AND LINE VALVECAUTIONAlways use a copper tube of the same diameter and length when replacing the hotgas

Page 37 - 2. BRAZING

4211) Connect the new Solenoid leads.12) Attach the Solenoid to the valve body, and secure it with a screw.13) Replace the panels in their correct pos

Page 38

438. REMOVAL AND REPLACEMENT OF WATER REGULATING VALVE - WATER-COOLED MODEL ONLYIMPORTANTAlways install a new Drier every time the sealed refrigera

Page 39

449. ADJUSTMENT OF WATER REGULATING VALVE - WATER-COOLEDMODEL ONLYThe Water Regulating Valve (also called “WATER REGULATOR”) is factory-adjusted. Noa

Page 40

4510. REMOVAL AND REPLACEMENT OF CONDENSING PRESSURE REGULATOR (C.P.R.) - REMOTE AIR-COOLED MODEL ONLYIMPORTANTAlways install a new Drier every t

Page 41

46Foam Insulation Thermistor HolderThermistor Lead Cable TieFig. 211. REMOVAL AND REPLACEMENT OF THERMISTORCAUTION1. Fragile, handle very carefully.2.

Page 42

4712. REMOVAL AND REPLACEMENT OF FAN MOTORNote: When replacing a Fan Motor with defective winding, it is recommended that a new capacitor be

Page 43 - WATER-COOLED MODEL ONLY

4813. REMOVAL AND REPLACEMENT OF WATER VALVE1) Turn off the power supply.2) Close the Water Supply Line Shut-off Valve.3) Remove the Front Panel.4) Re

Page 44 - MODEL ONLY

497) Remove the closed end connectors from the Pump Motor leads.8) Remove the two screws and the Pump Motor Bracket.9) Remove the Pump Housing, and ch

Page 45

5I. SPECIFICATIONS1. KM-2000SWF3, KM-2000SWH3 (Water-cooled) We reserve the right to make changes in specifications and design without prior notic

Page 46 - Thermistor Lead Cable Tie

50VI. CLEANING AND MAINTENANCE INSTRUCTIONS1. PREPARING THE ICEMAKER FOR LONG STORAGEIMPORTANTEnsure all components, fasteners and thumbscrews are se

Page 47

51[2] Remove the water from the potable water supply line:1) Remove the Front Panel. (Except water-cooled model)2) Move the Control Switch, on the Co

Page 48

522. CLEANING PROCEDUREIMPORTANTEnsure all components, fasteners and thumbscrews are securely in place afterany maintenance or cleaning is done to the

Page 49

53[a] CLEANING PROCEDURE1) Dilute 38 fl. oz. of the recommended cleaner Hoshizaki “Scale Away” or “LIME-A-WAY” (Economics Laboratory, Inc.) with 7

Page 50

5419) Turn on the power supply to fill the Water Tank with water.20) Turn off the power supply after 3 minutes.21) Remove the Front Panel, and fully o

Page 51

55[b] SANITIZING PROCEDURE - Following Cleaning Procedure1) Dilute a 5.25% Sodium Hypochlorite solution (chlorine bleach) with water (Add 3.5 fl.

Page 52 - 2. CLEANING PROCEDURE

563. MAINTENANCEIMPORTANT This icemaker must be maintained individually, referring to the instruction manual and labels provided with the icem

Page 53

62. KM-2000SRF3, KM-2000SRH3 (Remote air-cooled) We reserve the right to make changes in specifications and design without prior notice.

Page 54

73. CONDENSING UNITURC-20F

Page 55

8 SPECIFICATIONSMODEL: URC-20FEXTERIORDIMENSIONS (W x D x H)REFRIGERANT CHARGEURC-20FWEIGHTCONNECTIONSREFRIGERANTELECTRICALCONDENSERHEAD PRESSURE CONT

Page 56 - 3. MAINTENANCE

9 Evaporator Spray Tube Water Valve Expansion Valve Water Supply InletCheck ValveHot Gas ValveJunction BoxControl BoxWater-cooledCondenser

Commentaires sur ces manuels