13II. Installation and Operating Instructions WARNING1. This icemaker must be installed in accordance with applicable national, state, and local codes
14B. How to Remove PanelsSee Fig. 1 or Fig. 2•FrontPanel:Removethescrew.Liftupandtowardsyou.Disconnecttheconnectoronpush-button models.
15C. LocationCAUTION1. This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within 45°F to 100°F (7°C to 38°C
16E. Electrical Connection WARNING1. Electrical connection must be hard-wired and must meet national, state, and local electrical code requirements. F
17F. Water Supply and Drain ConnectionsSee Fig. 4, 5, or 6 WARNING1. Water supply and drain connections must be installed in accordance with applicabl
181. Icemaker•Icemakerwatersupplyinletis1/2"femalepipethread(FPT).Aminimumof1/4"nominalID copper water tubing or equivalent
19Condenser Water Supply Inlet1/2"FPTCondenser Drain Outlet 3/8"FPTIcemaker Water Supply Inlet1/2"FPTDrip Tray Drain Outlet 3/4"
2IMPORTANTOnly qualied service technicians should install, service, and maintain the icemaker. No installation, service, or maintenance should be und
20b) Connection to a Closed Loop System •Condenserwatersupplyinletis1/2"femalepipethread(FPT).Aminimumof1/4"nominalID copper
21G. Final Checklist WARNINGCHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that
22H. Startup WARNING1. All parts are factory-adjusted. Improper adjustments may adversely affect safety, performance, component life, and warranty cov
23Fig. 88) Remove the front panel, then remove the storage bin cover.9)Movethecontrolswitchtothe"ICE"position.10) Conrm bin contro
24III. Cleaning and MaintenanceThis icemaker must be cleaned and maintained in accordance with the instruction manual and labels provided with the ice
25A. Cleaning and Sanitizing InstructionsHoshizaki recommends cleaning and sanitizing this unit at least twice a year. More frequent cleaning and sani
268) Allow the icemaker to sit for 10 minutes before operation. If you placed a clamp on the reservoir hose in step 6, remove it before operation.9) I
27c) Sanitizing SolutionDilute0.82.oz.(25ml)ofa5.25%sodiumhypochloritesolution(chlorinebleach)with1.6 gal. (6.0 l) of warm water.d) Sa
284) Remove the motor bracket thumbscrews, rst from the vertical plane and then from the horizontal plane. While holding on to the corresponding agit
29B. MaintenanceThe maintenance schedule below is a guideline. More frequent maintenance may be required depending on water quality, the icemaker&apos
3CONTENTSImportant Safety Information ... 4I. Specicati
30C. Preparing the Icemaker for Long StorageCAUTIONWhen storing the icemaker for an extended time or in sub-freezing temperatures, follow the instruct
312. On water-cooled model only, remove the water from the water-cooled condenser:1)Makesurethecontrolswitchandthepowerswitchareinthe&quo
32HOSHIZAKI AMERICA, INC.618 Hwy. 74 S., Peachtree City, GA 30269 USA TEL (770) 487-2331 FAX (770) 487-3360 www.hoshizaki.com 91A2GG10A
4Important Safety InformationThroughout this manual, notices appear to bring your attention to situations which could result in death, serious injury,
5MODEL NUMBER DCM-751BAHSERIAL NUMBERAC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 115V 77LRA 14.6RLAGEAR MOTOR 120V 3.0FLA 1/4HPFAN MOTOR 120V 1.0FLA 50W
6MODEL NUMBER DCM-751BAH-OSSERIAL NUMBERAC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 115V 77LRA 14.6RLAGEAR MOTOR 120V 3.0FLA 1/4 HPFAN MOTOR 120V 1.0FLA
7 HOSHIZAKI ICE MAKER 3. DCM-751BWH (water-cooled)The rating label and nameplate provide electrical and refrigerant data. The rating label can be seen
84. DCM-751BWH-OS (water-cooled)The rating label and nameplate provide electrical and refrigerant data. The rating label can be seen by removing the f
9B. Dimensions/Connections1. DCM-751BAH (air-cooled)Unit: mm [in.]Rear ViewSide ViewFront ViewTop ViewSide View