6. ELECTRICAL CONNECTION6. ELECTRICAL CONNECTION
6. ELECTRICAL CONNECTION6. ELECTRICAL CONNECTION
6. ELECTRICAL CONNECTION
WARNINGWARNING
WARNINGWARNING
WARNING
1. Electrical connection must be made in accordance with the instructions on
a “WARNING” tag, provided with the pig tail leads in the Junction Box.
2. This icemaker requires a ground that meets the national and local electrical
code requirements. To prevent possible electrical shock to individuals or
extensive damage to the equipment, install a proper ground wire to the
icemaker.
• On three phase models, the Voltage Tap Switch in the unit should be positioned to match
incoming voltage at start-up. See Fig. 6.
• This icemaker must have a separate power supply or receptacle of proper capacity. See
the Nameplate.
• The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.
• When excessive voltage is supplied to the Controller Board, the icemaker stops running
in 3 seconds. See “10. START UP.”
• Usually an electrical permit and services of a licensed electrician are required.